Heat & Glo LifeStyle 6000XLSB Gas Heater User Manual


 
14
V H
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6' MAX. (1.86m)
4' MIN. (1.22m) 8' MAX. (2.4m)
V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m)
NOTE: On vertical venting configurations
where the vertical component is over 10
feet, you may want to install the vertical
baffle included in the manual bag assembly
to improve flame appearance.
Figure 7. Venting with One 90° Elbow
VENTING WITH ONE (1) 90° ELBOW
Figure 8. Venting with Two 90° Elbows
VENTING WITH TWO (2)
90° ELBOWS
V H H + H
1
1´ MIN. (305 mm) 2´ MAX. (610 mm) 6´ MAX. (1.82m)
2´ MIN. (610 mm) 4´ MAX. (1.22 m) 12´ MAX. (3.65m)
3´ MIN. (914 mm) 6´ MAX. (1.86 m) 18´ MAX. (5.48m)
4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 24´ MAX. (7.31m)
V+H+H
1
= 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H
1
= 24´ MAX. (7.31m)