Heat Controller VMH24SC-1 Heat Pump User Manual


 
34
Service Manual VMH SERIES Heat Controller, Inc.
33
8.4.8.3 Timer setting is available
8.4.8.4 When user uses timer off function in sleep mode (or sleep function in timer off mode), if the timing is
less than 7 hours, sleep function will be cancelled when the set time reached. If the timing is more than 7
hours, the machine will not stop until it reaches the set time in sleep mode.
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart module.
In case of a power failure, the module memorizes the set conditions before the power failure. The unit will
resume the previous operation setting (not including Swing function) automatically after 3 minutes when
power is restored.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes and
turn to auto mode as 75°F/24°C set temp.
If A/C is off before power off and A/C is required to start up, the compressor will have a 1 minute delay. All
other conditions, the compressor will have 3 minutes delay when restarts.
8.4.10 Automatic front panel function:
8.4.10.1 The automatic front panel is forced to turn to the moves to closed position at an angle of 50°when
the unit is turned off and is not affected by any signal from remote controller.
8.4.10.2 When the unit is turned on, the panel opens automatically at an angle of 50°, then the horizontal
louver will open.
8.4.10.3 When the unit is turned off, the panel is closed automatically at an angle of 50°, then the horizontal
louver will close.
8.4.10.4 If the panel requires moving while the horizontal louver is operating, the horizontal louver will stop
and then carry out the action of the panel. After ending the action of the panel, the horizontal louver will
continue its action.
8.4.11 Ionizer (Clean Air) function
8.4.11.1 Clean Air function is available only when the A/C is on, and it’s controlled through remote
controller.