Heat Controller MSS-012B/A Air Conditioner User Manual


 
Test
Mode
0
Test
operation
will
be
set
by
pushing
the
"Test
key"
on
the
main
PWB
Assy.
Each
test
operation
by
pushing
count
of
'Test
key"
is
as
well
as
the
following.
(1)
Indoor
"
Once
push
:
Ignore communication error.
"
Twice
push
:
Shorten
the
proceeding
time.(1
min
-+
1
sec)
"
3
Times
push
:
Shorten
the
proceeding
time.(1
hour-
1
sec)
"
4
Times
push
:
All
LED
ON
"
5
Times
push
:
Up/Down
Step
Motor
ON.
"
6
Times
push
:
Right
Step
Motor
ON.
(Not
on
all
Models)
"
7
Times
push
:
Left
Step
Motor
ON.(Not
on
all
Models)
"
8
Times
push
:
Negative
Ion
ON.(Not
on
all
Models)
"
9
Times
push
:
Reset.
Note)
For
normal
operation
after
checking
by
test
mode,
you
should
reset
main
power.
(2)
Outdoor
"
Once
push
:
Ignore Communication
error.
"
Twice
push
:
Comp.
ON,
Outdoor
Fan
ON
Reversing
Valve
Coil
ON(only
Heating
Model)
Crank
Case
heater
Coil
ON(only
Heating
Model)
"
3
Times
push
:
Comp.
ON,
Outdoor
Fan
ON
Reversing
Valve
Coil
OFF(only
Heating
Model)
Crank
Case
Heater
Coil
OFF(only Heating
Model)
"
4
Times
push
:
Same
"
5
Times
push
:
Error
LED(Red)
ON
"
6
Times
push
:
Comp
OFF,
Outdoor
FAN
OFF
"
7
Times
push
:
Reset
Note)
For
normal
operation after
checking
by
test
mode,
you
should
reset
main
power.
-22-
0