Heat Controller MSH-0186/A Air Conditioner User Manual


 
Connection
method
of
the
connecting
-cable(Example)
(1)
Dismount
two-caps
on
the
conduit
panel.
(2)
Make
a
hole
appropriate
for
the
passage
of
connection
cable
through
on
cap
by
tool.
(for
low
voltage
line)
(3)
Pass
the
connecting
cable
through
the
hole.
(4)
Property
connect
the
cable
on
the
terminal
block
(5)
Fix
the
connection
cable
with
clamp
cord
provided
on
the
unit
not to
have
strain
at
the
terminal
when
the
connection
cable
Is
pulled
outside
up
to
a
35
pound
weight.
(6)
Wind
the
vinyl
tape
round
the
connecting
cable
for
sealing
between
the
surface
of
the
connection
cable
and
cap.
(7)
Mount
the
taped
part
of
cable
on
the cap.
(8)
Finally,
mount
the
holed
cap
with
the
wound
cable
on
the
conduit
panel.
INEM3
Loose
wiring
may
cause
the
terminal
to
overheat
or
result
in
unit
malfunction.
A
fire
hazard
may
also
exist. Therefore,
be
sure
all
wiring
is
tightly
connected.
When
connecting
each
power
wire
to
the
corresponding
terminal,
follow
instructions
"How
to
connect
wiring
to
the
terminals'
and
fasten
the
wire
tightly
with
the
fixing
screw
of
the
terminal
plate.
For
strand
wiring
(1)
Cut
the
wire
end
with
a
wire
cutter
or
wire-culling
pliers,
then
strip
the
insulation
to
expose
the
strand
wiring
about
10mm(318').
(2)
Using
a
screwdriver,
remove
the
terminal
screw(s)
on
the
terminal
plate.
(3)
Using
a
round
terminal
fastener
or
pliers,
securely
clamp
each
stripped
wire
end
with
a
round terminal.
(4)
Position
the
round
terminal
wire,
and
replace
and
tighten
the
terminal
screw
using
a
screwdriver.
Clamp
cord
Cap(Reuse)
Hole
(VINN)
Taping
(for
sealing)
Low
voltage
line
(connecting
cable)
block
00
j
Lock
nut
Cap
(Remove)
Power
supply
line
(t
e,2sanoev)
panel
Strand
wire
ýý
b
O
Round
terminal
n
1
Screw
with
especial
washer
*Roundterminal
Samwkh
specialwasher
malplate
Wire
Wire
"
"
-34-
"