Heat Controller MMC18DA-1 Air Conditioner User Manual


 
Drill the piping hole with a Ø 70 mm (Ø 2.75 inch) hole core drill. Drill the piping hole at either
the right or the left with the hole slightly slanted to the outdoor side.
Drilling the hole in the wall
5-7 mm
(0.2"~0.3")
Indoor
WALL
Outdoor
10 Wall Mounted Multi-Zone Split System Air Conditioner
Installation of Indoor, Outdoor Unit
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing
of the wiring to power outlets is through the
walls typically.
Mounting Installation Plate
Installation Plate
Type "A" screw
Chassis
Hook
Installation plate
Left rear piping Right rear piping
Ø 70 mm
Ø 2.75 inch
Ø 70 mm
Ø 2.75 inch
D
B
A
C
ABCD
9K BTU/h 50 (1.97) 105 (4.13) 59 (2.32) 105 (4.13)
12K BTU/h 65 (2.56) 110 (4.33) 85 (3.35) 110 (4.33)
CHASSIS
(Grade)
Distance mm (inch)