Heat Controller MGD60-E3A Furnace User Manual


 
MGD Series Gas Furnace Installation Instructions
Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 1
INSTALLATION INSTRUCTIONS
SEALED COMBUSTION
DOWNFLOW MGD SERIES
GAS FURNACE SIZES 60, 75, 90
FOR INSTALLATION IN: MANUFACTURED (MOBILE) CAUTION: READ ALL SAFETY GUIDES
HOMES, RECREATIONAL VEHICLES, PARK MODELS, BEFORE INSTALLING THIS FURNACE
MODULAR HOMES AND BUILDINGS
GENERAL INFORMATION
These down flow sealed combustion furnaces install in
Manufactured Homes, Recreational Vehicles or Modular
Construction. The furnaces conform to Part 3280 (a) (2) of
HUD Manufactured Homes Construction and Safety
Standards. They must be installed only with listed RJ-Roof
Jack, Sealed Combustion venting system.
NOTE: These instructions are intended to assist qualified
individuals experienced in the installation of heating
equipment.
Some state and local codes require installation personnel to be
licensed. Read all instructions before starting the installation.
SAVE THIS MANUAL
NOTICE – Furnace set-up and any adjustment needed is
responsibility of the installer/ retailer/ contractor and is not
covered by the furnace manufacturers warranty.
CHECKLIST: FURNACE START-UP
1. Has furnace roof jack crown been correctly installed?
2. Has the furnace gas valve and burner orifice been
cleaned?
3. Is the gas line outlet pressure set for the fuel used?
4. If the home uses a crossover air connector duct, is it
installed per homebuilders installation instructions?
5. Has furnace been operated through complete heating
cycle?
WARNING-RISK OF FIRE OR ELECTRICAL SHOCK
Only qualified service personnel shall be used to install
and provide maintenance of this furnace.