Heat Controller HAH13XX-00-1A Air Cleaner User Manual


 
ELECTRIC HEATER KIT SPECIFICATIONS
kW@
MINIMUM CIRCUIT
AMPACITY
MAX. FUSE OR
BREAKER (HACR)
MODEL
USED WITH
240V 208V 240V 208V 240V 208V
N/A Without heat 0 0 2.1 1.9 15 15
7800-305B 5.0 3.8 29 25 30 25
7800-306B 8.0 6.0 44 39 45 40
7800-308B
HAH1324-00-1A
10 7.5 55 48 60 50
N/A Without heat 0 0 3.5 3.4 15 15
7800-305B 5.0 3.8 30 27 30 30
7800-306B 8.0 6.0 46 40 50 40
7800-308B 10 7.5 56 49 60 50
7800-312B
HAH1336-00-1A
15 11.3 56/26 49/23 60/30 50/30
N/A Without heat 0 0 4.0 3.9 15 15
7800-313B 5.0 3.8 30 27 30 25
7800-314B 8.0 6.0 46 41 50 45
7800-315B 10 7.5 57 50 60 50
7800-316B 15 11.3 53/30 46/27 60/30 50/30
7800-317B
HAH1348-00-1A
20 15 57/63 50/46 60/60 50/50
N/A Without heat 0 0 6.0 5.9 15 15
7800-313B 5.0 3.8 32 29 35 30
7800-314B 8.0 6.0 48 42 50 45
7800-315B 10 7.5 59 52 60 60
7800-316B 15 11.5 53/32 46/29 60/35 50/30
7800-317B
HAH1360-00-1A
20 15 59/53 52/46 60/60 60/50
7800-400 4-Pole Jumper Bar Assembly 15 and 20 kW only
HAHIOM062906