POWER CONNECTION OPTIONS
Appropriate power cord accessory kit is determined by the voltage, and amperage of the branch circuit. The unit does not come
with a power cord (or hard wire kit). An accessory power cord kit must be ordered to connect the unit to the outlet. If the unit is
to be hard wired, an accessory hard wire kit must be ordered.
IMPORTANT: For 265V units, if a power cord is selected, it must plug into the 265V subbase accessory.
Cord-connected Units
The 250V eld supplied outlet must match the plug for the standard 208/230V units and be within reach of the service cord.
The standard cord-connected 265V units require an accessory electrical subbase for operation. Refer to Table for proper recep-
tacle and fuse type.
Power Cord Protection
The power cord for 230/208v units provide power cord re protection.Unit power automatically disconnects when unsafe conditions
are detected. Power to the unit can be restored by pressing the reset button on plug head. Upon completion of unit installation for
230/208V models, an operational check should be performed using the TEST/RESET buttons on the plug head.
NOTE: The 265V models do not incorporate this feature as they require use of the electrical subbase accessory.
RECEPTACLES AND FUSE TYPES: 250, 265 VOLTS
LEGEND
HACR—Heating, Air Conditioning, Refrigeration * May be used for 15 amp applications
230/208 VOLT
N/A*
7602-530A-230
265 VOLT
N/A*
7602-530A-265
230/208 VOLT
7602-520A-230
265 VOLT
7602-520A-265
230/208 VOLT
7602-515A-230
265 VOLT
7602-515A-265
EKTC07-1G
EKTH07-1G
EKTC09-1G
EKTH09-1G
EKTC12-1G
EKTH12-1G
EKTC15-1G
EKTH15-1G
EKTC07-2G
EKTH07-2G
EKTC09-2G
EKTH09-2G
EKTC12-2G
EKTH12-2G
EKTC15-2G
EKTH15-2G
CODE OF POWER SUPPLY KIT
30A 20A 15A
UNIT MODEL
* Using 30A on these units could result in damage to your unit.
Power Connection Chart