Heat Controller A-MMH36FA-1 Air Conditioner User Manual


 
- 24 -
Wall Mounted Multi-Zone Split System Air Conditioner
Flaring Work and Connection of Piping
Check
1. Compare the flare work like the figure on the right.
2. If a flared section is defective, cut it off and repeat the flar-
ing process again.
Indoor
1. Prepare the indoor unit's piping and drain hose for installation through the wall.
2.
Remove the plastic tubing retainer(see illustration on the
right) and pull the tubing and drain hose away from chassis.
1. Route the indoor tubing and the drain hose in the direction
of rear right.
2.
Insert the connecting cable into the indoor unit from the out-
door unit through the piping hole.
• Do not connect the cable to the indoor unit.
Make a small loop with the cable for easy connection later.
3. Tape the tubing, drain hose, and the connecting cable. Be
sure that the drain hose is located on the lowest side of the
bundle. Locating on the Upper side can cause the conden-
sation to overflow in the drain pan inside the indoor unit.
If the drain hose is routed inside the room, insulate the hose
with an insulation material* so that dripping from "sweat-
ing"(condensation) will not damage furniture or floors.
*Foamed polyethylene or equivalent is recommended.
Inclined
Inside is shiny without scratches
Smooth all around
Even length
all around
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
Connecting the Piping
For right rear piping
Drain hose
Connecting
pipe
Connecting cable
Tape
Drain hose