Heat Controller 7.5 Air Conditioner User Manual


 
24
072A-3L NONE ——37/37 50/50
CC10C 7.2/9.6 20.0/23.1 37/37 50/50
CC15C 10.8/14.4 30.0/34.6 45/51 50/60
CC20C 14.4/19.2 40.0/46.2 57/65 60/70
CC30C 21.6/28.8 60.0/69.3 82/94 90/100
085A-4L NONE ——42/42 60/60
CC10C 7.2/9.6 20.0/23.1 42/42 60/60
CC15C 10.8/14.4 30.0/34.6 48/54 60/60
CC20C 14.4/19.2 40.0/46.2 60/68 60/70
CC30C 21.6/28.8 60.0/69.3 85/97 90/100
CC40C 28.8/38.4 80.1/92.4 111/126 125/150
090A-4L NONE ——43/43 50/50
CC10C 7.2/9.6 20.0/23.1 43/43 50/50
CC15C 10.8/14.4 30.0/34.6 48/54 50/60
CC20C 14.4/19.2 40.0/46.2 60/68 60/70
CC30C 21.6/28.8 60.0/69.3 85/97 90/100
CC40C 28.8/38.4 80.1/92.4 111/126 125/150
102A-4L NONE ——54/54 60/60
CC10C 7.2/9.6 20.0/23.1 54/54 60/60
CC15C 10.8/14.4 30.0/34.6 54/60 60/60
CC20C 14.4/19.2 40.0/46.2 67/74 70/80
CC30C 21.6/28.8 60.0/69.3 92/103 100/110
CC40C 28.8/38.4 80.1/92.4 117/132 125/150
UNIT MODEL
NUMBER
PCG-
XIX. HEATER KIT CHARACTERISTICS
TABLE A
A
UXILIARY HEATER KITS CHARACTERISTICS AND APPLICATION (PCG MODELS)
208/240V – 3 PHASE
HEATER KIT
MODEL NO.
RXJJ-
HEATER kW
@ 208/240 V/
3 PHASE
HEATER KIT FLA
UNIT MIN. CKT.
AMPACITY
MAX. FUSE OR
CKT. BKR. SIZE
(CKT. BKR. MUST
BE HACR TYPE
FOR USA)