Hearth and Home Technologies SL-950TR-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. L • 11/0876
B. Vent Components Diagrams (continued)
Figure 16.7 SLP Series Vent Components
Figure 16.6 DVP vent components
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-
SS termination caps on top vented replaces,
a one foot minimum vertical vent section is
required before installing rst elbow.
WARNING
13 in.
(330 mm)
15 in.
(381 mm)
8-1/8 in.
(206 mm)
10-7/8 in.
276 mm
10-1/2 in.
267 mm
87°
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in.
140 mm
8-3/8 in.
213 mm
13 in.
(330 mm)
15 in.
(381 mm)
8-1/8 in.
(206 mm)
10-7/8 in.
276 mm
10-1/2 in.
267 mm
87°
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in.
140 mm
8-3/8 in.
213 mm
DVP-HRC-SS
DVP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
SLP-HRC-SS
SLP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
DVP-TB1
HORIZONTAL TERMINATION CAP
• When using DVP-TB1 termination cap on top vented
replaces, a three foot minimum vertical vent section is required
before installing rst elbow.
SLP90
SL-2DVP
DVP-TB1
DVP-TB1
ASSEMBLY