Hearth and Home Technologies SL-550TRS-E Indoor Fireplace User Manual


 
20
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. G • 11/08
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf c and away from furniture and draperies.
NOTICE: Illustrations re ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
K
C
A
L
F
I
B
G
E
D
J
J
G
A
F
C
A
H
M
N
Models A B C D
E
Min.
F
Min.
GH I JKLM N
SL-750TRS-IPI-E
SL-750TRS-E
in. 45-1/2 42 64-3/8
See Section
5.D for Alcove
Installation
1 1/2 45-1/2 64-3/8 16-1/4 48-1/2 68-3/4 16-5/8 7-1/2 9
mm 1155 1067 1635 25 13 1155 1635 413 1232 1737 422 191 229
SL-550TRS-IPI-E
SL-550TRS-E
in. 42 37 59-1/2 1 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2 7-1/8
mm 1067 940 1511 25 13 1117 1581 413 1232 1737 383 191 181
SL-350TRS-IPI
in. 39-1/2 34 55-7/8 1 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 13-1/2 7-1/2 6
mm 1003 864 1413 25 13 1117 1581 413 1232 1737 343 191 152