Hearth and Home Technologies RCOR-HVB-IPI Indoor Fireplace User Manual


 
27
Figure 19. Venting with three 90° elbows
V
H
H
1
V
1
V
H
H
1
V
1
NATURAL GAS
VENTING WITH THREE 90° ELBOWS
V + V
1
(FT.) H + H
1
(FT.)
90
0
Elbow on top 2.5’ MAX. (64mm)
1' MIN. (305mm) 3' MAX. (914mm)
2' MIN. (610mm) 6' MAX. (1.83m)
3' MIN. (914mm) 9' MAX. (2.7m)
4' MIN. (1.22m) 12' MAX. (3.6m)
5’ MIN. (1.5m) 15’ MAX. (4.5m)
6’ MIN. (1.83m) 18’ MAX. (5.5m)
V+ V
1
+ H + H
1
= 50’ MAX. (15.2m)
PROPANE
VENTING WITH THREE 90° ELBOWS
V + V
1
(FT.) H + H
1
(FT.)
90
0
Elbow on top 2’ MAX. (610mm)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6’ MAX. (1.83m)
4' MIN. (1.22m) 8' MAX. (2.4m)
5’ MIN. (1.5m) 10' MAX. (3.0m)
6’ MIN. (1.83m) 12' MAX. (3.6m)
V+ V
1
+ H + H
1
= 50’ MAX. (15.2m)
H + H
1
= 12’ MAX. (3.6m)
H + H
1
= 18’ MAX. (5.5m)