Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. F • 7/08
6
TOP VIEW
A
C
B
3
3
Fireplace Size Requirements
Figure 3.1 Fireplace Opening
NOTE: For actual appliance dimensions refer to Section 16.
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffi c areas.
WARNING
Minimum Appliance Size
Location QVI35S QVI30S
Inches Millimeters Inches Millimeters
A Front Width 33-1/4 845 29-1/4 743
B Rear Width 24-1/4 616 20-1/4 515
C Depth 13-5/8 346 13-5/8 346
* Height 22-3/4 578 20-1/4 515
* NOTE: If exhaust collar on insert and fi replace damper do not line up, add 4
inches (102mm) to minimum fi replace height for bends in vent pipe.
A. Minimum Fireplace Opening
Minimum fi replace opening requirements are shown in
Figure 3.1.
• The fi rebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory built fi rebox in order to gain minimum gas insert
opening requirements.
• Any smoke shelves, shields, baffl es and the metal fl oor
of the unit may be removed from a factory built fi rebox if
attached with mechanical fasteners. If the appliance is
placed on the base of the outer wrap, a ¼ inch airspace
must be provided between the insert and the fl oor of the
outer wrap.
• Cutting of any sheet metal parts of the fi replace in which
the gas fi replace insert is to be installed is prohibited.