Hearth and Home Technologies NBV3630I Indoor Fireplace User Manual


 
Heatilator • Novus NBV • 4055-188 Rev C • 04/08 11
Measured from top of hood (in inches)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
5
5-1/2
6-1/4
7
7-3/4
8-1/2
9-1/4
10
10-3/4
11-1/2
12-1/4
13
13-3/4
14-1/2
15-1/4
16
30 in. minimum
to ceiling
Figure 3.3 Clearances to Mantels or Other Combustibles Above Appliance
1 in. (25 mm) min.
to perpendicular wall
A
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Figure 3.4 Clearances to Combustible Mantel Legs or Wall Projec-
tions (acceptable on both sides of opening)
D. Mantel Projections
Fire Risk
Comply with all minimum clearances to combustibles as speci ed.
• Framing or nishing material used on the front of, or in front of, the appliance closer than the minimums
listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause re.
WARNING