Hearth and Home Technologies LCOR-HVB-IPI Indoor Fireplace User Manual


 
24
Figure 15. Venting with Two 90° Elbows
H
1
H
V
V
V
1
H
NATURAL GAS
VENTING WITH TWO 90° ELBOWS
V (FT.) H + H
1
(FT.)
90
0
Elbow on top 2.5’ MAX. (64mm)
1' MIN. (305mm) 3' MAX. (914mm)
2' MIN. (610mm) 6' MAX. (1.83m)
3' MIN. (914mm) 9' MAX. (2.7m)
4' MIN. (1.22m) 12' MAX. (3.6m)
5’ MIN. (1.5m) 15’ MAX. (4.5m)
6’ MIN. (1.83m) 18’ MAX. (5.5m)
V + H + H
1
= 50’ MAX. (15.2m)
PROPANE
VENTING WITH TWO 90° ELBOWS
V (FT.) H + H
1
(FT.)
90
0
Elbow on top 2’ MAX. (610mm)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6’ MAX. (1.83m)
4' MIN. (1.22m) 8' MAX. (2.4m)
5’ MIN. (1.5m) 10' MAX. (3.0m)
6’ MIN. (1.83m) 12' MAX. (3.6m)
V + H + H
1
= 50’ MAX. (15.2m)
NATURAL GAS
VENTING WITH TWO 90° ELBOWS
V + V
1
(FT.) H (FT.)
90
0
Elbow on top 2.5’ MAX. (64mm)
1' MIN. (305mm) 3' MAX. (914mm)
2' MIN. (610mm) 6' MAX. (1.83m)
3' MIN. (914mm) 9' MAX. (2.7m)
4' MIN. (1.22m) 12' MAX. (3.6m)
5’ MIN. (1.5m) 15’ MAX. (4.5m)
6’ MIN. (1.83m) 18’ MAX. (5.5m)
V + V
1
+ H = 50’ MAX. (15.2m)
PROPANE
VENTING WITH TWO 90° ELBOWS
V + V
1
(FT.) H (FT.)
90
0
Elbow on top 2’ MAX. (610mm)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6’ MAX. (1.83m)
4' MIN. (1.22m) 8' MAX. (2.4m)
5’ MIN. (1.5m) 10' MAX. (3.0m)
6’ MIN. (1.83m) 12' MAX. (3.6m)
V + V
1
+ H = 50’ MAX. (15.2m)
H + H
1
= 18’ MAX. (5.5m)
H + H
1
= 12’ MAX. (3.6m)