NOTICE: DO NOT wire
110 VAC to wall switch.
E. Junction Box Installation
If the junction box is being wired from OUTSIDE of the
appliance (preferred method):
Remove two screws that attach junction box and bracket
to appliance. See Figure 12.2.
Feed an appropriate length of romex through plastic
romex connector.
Make necessary electrical connections.
Attach outlet and cover plate to junction box.
Reattach junction box and bracket to appliance with two
screws.
Figure 12.2 Remove Two Screws From Bracket
If the junction box is being wired from the INSIDE of the
appliance:
Remove one screw that attaches access panel to
column. See Figure 12.3.
Remove two screws that attach junction box to junction
box bracket. See Figure 12.4.
Feed an appropriate length of romex through plastic
romex connector.
Reattach junction box to junction box bracket with two
screws.
Make necessary electrical connections.
Attach outlet and cover plate to junction box.
Reattach cover plate to column with one screw.
Figure 12.3 Remove Access Panel Screw
Figure 12.4 Remove Two Screws Holding Junction Box