Hearth and Home Technologies I100 Indoor Fireplace User Manual


 
40
IMPORTANT! Hearth extension design must be
determined before installation of replace.
20 in. Min.
Hearth Extension
Floor
Noncombustible
Framing Material
Noncombustible
Finishing Material
Protective Metal
Hearth Strips
1/2 in. Micore
or equivalent
insulation
Figure 11.3 Raised Platform Hearth Extension Detail
Raised Hearth Extension Framing
The hearth framing must be constructed of non-combusti-
ble materials and placed on an HX4 or equivalent material
(Figures 11.2-11.4). When creating the platform, allow for
the thickness of the non-combustible nishing materials
(Figure 11.5).
1/2 in. Micore
or equivalent
Hearth must
extend at least
12 in. beyond
the fireplace
opening on both
sides.
20 in. Min.
Noncombustible
Framing Material
Figure 11.4 Raised Platform Hearth Extension-Framing Materials
Noncombustible
Finishing Materials
Figure 11.5 Raised Platform Hearth Extension-Finishing Materi-
als
2 in. (51 mm)
required
Continuous,
non-combustible sealant
Tile, stone or other
non-combustible material
Floor constructed of wood or
other combustible material
1/2 in. Micore
or equivalent
insulation
(see Table 11.2)
Fireplace
Protective
Metal Hearth
Strip
Figure 11.2 Hearth Extension Construction
Heatilator • I100 • 35144 • Rev AA • 11/08