Damper
Stop Clamp
Damper
Figure 8 Damper Stop Clamp
K. Damper Stop Installation Instructions
Included in the burner assembly box is a damper stop clamp
which attaches to the damper as shown (Figure 8). Install
the clamp to the damper ensuring that the minimum require-
ments (Tables 1 and 2) are achieved. Use a 7/16 in. wrench
to secure the clamp to the damper. If the damper clamp pro-
vided does not t your application, other means of securing
the proper opening must be provided by the installer.
Inspect the pilot burner to ensure it is clear of any
rock wool.
Remove the Platinum Bright Embers™ from the package.
For optimum performance peel each piece apart in layers
and lightly place on top of the vermiculite and rock wool
where the ame is blue. This will achieve the desired
realism.
The gas burns at the point of the least resistance. In
case of an uneven ame pattern it may be necessary to
adjust the materials in the pans (using an object such as
a screwdriver) to achieve the desired effect.
Place desired amount of lava granules on the oor of the
replace. DO NOT ALLOW THE GRANULES TO COME
IN CONTACT WITH THE FLAMES. (Lava granules may
contain moisture which, when heating, may cause it to pop
out during installation and set-up.) Ensure that the controls
and switches are unobstructed after the granules are
installed. DO NOT COVER THE AIR MIXER LOCATED
ON THE LOWER LEFT SIDE OF THE BURNER.
Place logs as shown in Sections S thru Z.
Place accent logs around burner on oor of replace.
Pour vermiculite into each burner pan to the point where
each pan is completely full. Level the vermiculite from right
to left to ensure an even ame pattern. See Figure 6.
J. For Propane Gas Installation (for all units).
Fire Risk
Explosion Risk
Personal Injury Risk
An explosion could occur if a connection is
made directly to an unregulated propane
(LP) tank.
WARNING
Lightly place dime size pieces of rock wool evenly on top
of the vermiculite to achieve a glowing ember effect. See
Figure 7.
Note: Be sure to not cover the pilot assembly (located on
the right side of the burner pan, installed in the vertical
position) with vermiculite.
Note: For best results, do not pack down the rock wool.
The placement of rock wool can have an effect on ame
pattern and may need to be adjusted to achieve a desired
appearance.
Fire Risk
Explosion Risk
Personal Injury Risk
Pour vermiculite into each burner pan (LP) to
the point where each pan is completely full.
Failure to do so may cause the lighting to be
delayed and this can be dangerous..
WARNING
Note: The state of Massachusetts requires that the
chimney ue damper, when used with gas logs, be welded
open or completely removed. In the Commonwealth of
Massachusetts this appliance must be installed by a
licensed plumber or gastter.