Hearth and Home Technologies GDCR4136I Indoor Fireplace User Manual


 
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. F • 11/0820
C
A
B
D
Figure 5.3 Clearances to Combustibles
G
F
I
I
E
H
* Adjust framing dimensions for interior sheathing (such as sheetrock)
GDFL4136I
GDFL4136
ABCDEFGHI
DVP Pipe SLP Pipe
Rough
Opening
(Height)
DVP Pipe*
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Inches
10 8-5/8 38-1/8 23 40 31-5/8 0 0 1/2 36
Millimeters
254 219 968 584 1016 803 0 0 13 914
C
A
B
D
Figure 5.4 Clearances to Combustibles
* Adjust framing dimensions for interior sheathing (such as sheetrock)
GDCR4136I
GDCL4136I
ABCDEFGHI
DVP Pipe SLP Pipe
Rough
Opening
(Height)
DVP Pipe*
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Inches
10 8-5/8 38-1/8 24 40 31-5/8 0 0 1/2 36
Millimeters
254 219 968 610 1016 803 0 0 13 914
G
F
I
I
E
H
H