Hearth and Home Technologies E39 Indoor Fireplace User Manual


 
10 17335 Rev L 07/04
E36/39/42 INSTALLATION INSTRUCTIONS
Figure 3
Installation Along a Wall or an Exterior Chase
Figure 4
Corner Installation
WARNING!
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.
Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the
roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will
reduce the possibility of fireplace smoking or air flow reversal.
WARNING!
To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers
or exposed insulation. Localized overheating could occur and a fire could result.
Figure 2 - Fireplace Locations
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a
room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations
of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of
the fireplace. Consideration should be given to these factors before deciding on a location.
CLEARANCES!
A minimum 1/2 in. air
clearance must be
maintained at the back and
sides of the fireplace
assembly.
Chimney sections at any level
require a 2 in. minimum air
space clearance between the
framing and chimney section.
D. PRE-INSTALLATION PREPARATION
Figures 3 and 4 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must
be made for 90-deg bends. Less space is required when ducting goes directly outside without forming elbows.
Cat #ABCDE
E/EC36
42 in.
1067 mm
72-3/4 in.
1848 mm
36-3/8 in.
924 mm
15-5/8 in.
397 mm
51-3/8 in.
1305 mm
E/EC39
45 in.
1143mm
75-3/4 in.
1924 mm
37-7/8 in.
962 mm
16-5/8 in.
422 mm
53-1/2 in.
1359 mm
E/EC42
48 in.
1219 mm
78-3/4 in.
2000 mm
39-3/8 in.
1000 mm
17-5/8 in.
448 mm
55-3/8 in.
1407 mm
Cat # A B
E/EC36
42 in
1067 mm
45 in.
1143 mm
E/EC39
45 in.
1143 mm
48 in.
1219 mm
E/EC42
48 in.
1219 mm
51 in.
1295 mm
These are
rough
framing
dimensions
only.