Hearth and Home Technologies CFL-30NG-C Indoor Fireplace User Manual


 
7
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST-CFL-24-B • 526-910 Rev. E • 10/08
Figure 3. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI
7. Test re the unit after referring to the SAFETY INFOR-
MATION and LIGHTING INSTRUCTIONS found in
Section 3 in this manual, or on the label plate assembly
found on the gas-burner.
8. After the gas line installation is complete, all connections
must be tightened and checked for leaks with a com-
mercially-available, non-corrosive leak check solution.
Be sure to rinse off all leak check solution following
testing. Refer to Section 3, OPERATING GUIDELINES
and MAINTENANCE INSTRUCTIONS.
9. Once the gas-burner is test red and gas supply lines
are purged, assemble the grate(s) and logs. Be certain
to follow the Log Placement Instructions shipped with
the unit. Remember to keep the Log Instructions along
with this manual for future use.
This appliance may be used with a wall switch and/or
remote control.
Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch.
Keep wire lengths as short as possible by removing any
excess wire length.
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
Installation and use of any damaged appliance
or vent system component.
• Modi cation of the appliance.
• Installation other than as instructed by Hearth &
Home Technologies.
Improper positionsing of the gas logs.
Installation and/or use of any component part
not approved by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING
BLACK
RED
BATTERY PACK
(BATTERIES REQUIRED)
WIRES
(TO BROWN)
ORANGE
GREEN
VALVE
GROUND TO
FIREPLACE
CHASSIS
WHITE
ORANGE
IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR
I
S
REMOTE OR
WALL SWITCH
Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
REMOTE
OR WALL
SWITCH
BLACK BLACK
ON/OFF
SWITCH
RED
THERMOPILE
WHITE
Figure 4.