Hearth and Home Technologies CB1200-B Stove User Manual


 
R
September 1, 2008
7014-082D
Page 9
CB 1200 Pellet Stove
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A
non-combustible floor protec-
tion is recommended extending beneath the flue pipe
when installed with horizontal venting or under the top
vent adapter with vertical installation.
CANADA INSTALLATIONS: A
non-combustible floor
protection extending beneath the flue pipe is r
equired
with horizontal venting or under the top vent adapter with
vertical installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
L*
K
K
M
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides 2 51
L*
Back 2 51
M
Front 6 152
Figure 9.1
Figure 9.2