Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/1234
Figure13.4FinishingMaterial1InchThickorLess
DOOR
1 in. MAX.
FINISHING MATERIAL
(TOP EDGE)
Finishing materials 1 inch maximum thick.
Stop nishing material ush with opening.
FINISHING STRIP NOT USED
NON-COMBUSTIBLE
FINISHING MATERIAL
C. Doors
Only doors certied for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used. Once you have determined what kind of door
and nishing material is going to be used on the replace,
you may use the table below which shows the door mod-
els and the nishing material thickness allowed.
NOTICE: See service parts list (Section 16.B) for ordering
nishing strips. Finishing strips will not be needed for all
“Inside Fit” doors.
DOOR FIT
FINISHMATERIAL
THICKNESS
SEE
FIGURE
Folio Inside Any 13.6
Arcadia
Overlap 1 inch or less 13.4
Inside Greater than 1 inch 13.5
Halston
Overlap 1 inch or less 13.4
Inside Greater than 1 inch 13.5
Chateau
Overlap 1 inch or less 13.4
Inside Greater than 1 inch 13.5
Galleria
Overlap 1 inch or less 13.4
Inside Greater than 1 inch 13.5
Phoenix Inside Any 13.6
Harbor Inside Any 13.6
Arts & Crafts Inside Any 13.6
Modernist Inside Any 13.6
Jamestown Inside Any 13.6
Finishing Material Thickness: 1 Inch Thick
orLess
Note:Finishing strips may be used to aid in positioning of
non-combustible facing materials for some of the door com-
binations in the table above. Use nishing strips with “Over-
lap” t doors. They must be removed following nishing
work. See gure 13.7.