11. Optional Hot Water Coil
(Not Available For Mark I)
PLUMBING DIAGRAM FOR THERMO-SIPHON METHOD - MAX. DISTANCE 10 FT.
COIL INSTALLATION (See Coil Diagram on Page 14)
Place one of the nuts supplied on each leg of the coil. Place coil through the holes in the back of the firebox and adjust the nuts so the pipes
stick out about 1 1/4 to 1 1/2 inches from the side of the stove. Put flat washers and nuts on the outside and tighten within 1/4 inch. Then
place fiberglass rope around each pipe the washers and tighten. You are now ready to run pipes.
THERMO-SiPHON METHOD (LESS THAN 10 FEET)
This is the simplest and most economical method, however, the hot water tank must be less than ten feet from the stove. The water inlet,
where the temp./press/relief valve is located, must be higher than the top leg of the coil. The hot water tank should be elevated, if necessary,
to allow for proper thermo-siphon action (the method by which hot water will circulate automatically through the system.)
a) Shut off the hot water heater and the old water supply to it. Drain the tank completely.
b) Remove the temp./press/relief valve and discard. Install a short 3/4" nipple and tee (1) along with a new temp./press/relief valve.
c) Run 3/4" copper tubing along with the necessary fittings between the hot water tank and the top leg of the water coil. Install a 3/4" vent
elbow and automatic “float type” air vent (2) in the high point of the line. Within two feet of the top leg of the water coil install a 150 lb.
pressure relief valve. (7) Run 3/4" tubing from the release exit of both relief valves downward (3) so the hot water may escape the event
of overheating.
d) Remove the drain valve at the bottom of the tank. Install a short 3/4" nipple and tee and re-install the drain valve to the tee (4). Run 3/4"
copper tubing with the necessary fittings between the drain/tee combination and the lower leg of the coil. After all of the connections have