4. If Starting After an Empty Hopper, Turn Feed
Adjuster to “TEST” (for one 60 second cycle).
This will feed pellets into the auger tube and also
allow you to check the motors for operation. NOTE:
The auger motor will not operate with any of the
doors open.
5. Turn Feed Adjuster to #4.
If this is your rst re or you are trying differ-
ent pellets, set the feed adjuster to #4, This is an
average number for most pellets and may need to
be adjusted for your particular fuel. After you know
a feed rate setting that works well for your applica-
tion, use that setting.
NOTE: You know your feed rate is too high when:
The overheat safety feature is energized each time
the heating zone demand turns off during a high burn.
OR, If unburned or partially burned pellets are found
in the ash pan.(this may also be an indication of a
burn pot in need of scraping.)
7. Turn the MAX. TEMP. Dial on the control
board to the desired temperature. This setting must
always be at least 5° F. higher than the MIN. TEMP.
setting.
6. Flip the Igniter Switch up into the “AUTO”
position.
WARNING: HOT WHILE IN OPERATION.
KEEP CHILD RE N, C LO THI NG, A ND
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.
WATER TEMPERATURE
MAX. TEMP.