3
DO NOT BURN WET COAL
WARNINGS
INTRODUCTION
This all new design by Harman features the Verti-Flow Stoker System.
This unique system provides a very wide range of heat output. The
Verti-Flow Stoker can operate from 5000 to over 85,000 btu's automatically.
This unit has a 100 pound coal capacity and can provide 85,000 btu's
for 17 hours or stretch out to over 100 hours when less heat is required.
A thermostat is used to regulate the heat output of the stove. When no
heat is needed, the stoker stops and only runs to maintain the fire. If heat is
needed, the thermostat can turn on the stoker at any time. After the thermostat
is satisfied, the stoker will turn off for twelve minutes and then run for four
minutes.
The four minutes "on" and twelve minutes "off" is a setting that will
perform well under most conditions. This "on" and "off" time can be changed
to provide more or less heat during the maintenance cycle.
This unit must be connected to a chimney capable of providing a .04
minimum draft reading. WARNING!! If the chimney has no draft, coal gases
may escape from the unit and stovepipe. These gases are toxic and can be
fatal. It is recommended that a gas detector be installed to warn of this
condition. Check with your local stove dealer for purchasing a gas detector.
100 LBS.
COAL
THERMOSTAT
Never sleep in the same
room with any coal
burning stove.
TESTING INFORMATION
This unit has been tested and approved by OMNI-TEST Labo-
ratories in accordance to the listed codes.