Re-set the High Temperature Limit Stop (optional)
Close the drain OR cover it with a wash cloth.
Use the included 4 mm Allen wrench to push the
screw cover into the handle. Retrieve the screw
cover when the handle is removed.
Use the 4mm Allen wrench to loosen the handle
screw 4 complete revolutions. Remove the
handle and put it in a safe place.
Remove the decorative nut cover and put it in a
safe place.
Remove the handle screw from the stem of the
cartridge. Remove the high temperature limit
stop.
Replace the high temperature limit stop so that
the pin on the cartridge is in the desired slot on
the limit stop. Note: the temperatures given in
the diagram assume a water heater temperature
of 140
o
F, a cold water temperature of 50
o
F
and a water pressure of 45 PSI.
Replace the decorative nut cover. Replace the handle screw. Use the Allen wrench to turn the
screw 4 revolutions.