Haier HSU-12HSA03/R2(DB) Air Conditioner User Manual


 
Haier air conditioner Edition:20070116
-19-
7.3 Timer ON/OFF
The executing order is based on the direction from the board.
. Sleep operatingĐ
8.1 During cool/ dry operation, the fixed temperature will rise by 1ć after it operates for 1 hour. After
another hour the temperature will rise by another 1 . After 6 hours, the unit is off.ć
8.2 During heat-making operation, the fixed temperature will rise by 2 after 1 hour. After another 2ć
hours the temperature will rise by 2 . The temperature will rise by 1 after three hours. After the lastćć
3 hours, the unit is off.
8.3 Indoor fan unit will be high fan before the unit is set for sleeping state. After it is set for sleeping
state, fan speed indoors will change into middle fan speed. If indoor fan unit is middle fan speed before
it is set for sleeping state, fan speed indoors will change into low fan after it is set for sleeping state. If
indoor unit is low fan before it is set for sleeping state, fan speed indoors will keep the same.
. Automatic operationđ
The automatic operation is divided into automation and full automation by use the variant selection
mode.
9.1 Automation operating mode:
Automation operating is on, MCU will select corresponding operation mode based on the room
temperature to preserve the set temperature (set temperature is 23 in the heat mode; it is 26 inćć
the cool mode).
For the first power on, if the indoor temperature T=23 the system will operate in the heat mode,ć
T>23 operating in the cool mode.ć
The system will perform the heat program in the heat mode (set temperature is 23 ), when systemć
temperature arrive at stop value of compressor, the compressor to off and waiting for 3 minutes; after
the compressor stop continuance for 15 minutes, if the system detected the ventilation temperature is
more than 23 , it will enter cool mode, or else it will continuously operate in the heat mode.ć
When enter the cool mode and the system operating in cool mode (set temperature 26 ), theć
compensation temperature contrast will be canceled automatically, when it arrive at the stop
temperature of the compressor, the compressor to off and wait for 3 minutes; after the compressor
stop continuously for 15 minutes, the system detected the ventilation temperature T=23 , then it wć ill
enter heat mode and automatically add the compensation temperature. or else it will continuously
operate in the cool mode.