Outdoor Unit
4
OUTLET
INLET
CONNECTING PIPING
AND ELECTRICAL WIRING
DRAIN HOSE
4
Actual inlet grille may vary from the one shown in the
manual according to the product purchased
Parts and Functions
Indoor Unit
Remote controller
Inlet
grille
Air Purifying
Outlet
Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
(adjust left and
ow)
Vertical blade
Filter
Anion
generator
(inside)
right air fl
Inlet
TEMP display
Display board
COOL: blue
AUTO: white DRY: cyan
FAN: yellow
: green
Nano-Aquo
Aureole
Display modethe aureole display different
colour when setting different function
Nano-Aquo
Generator
inside
10.
12.
SWING LEFT/RIGHT button
13.
15. SLEEP display
14. HEALTH display
16.
18. POWER/SOFT display
20. TEMP display
21.
TIMER OFF/ON
22.
2
1. Mode display
1
2
3
4
5
15
16
HEALTH
SLEEP
TIME
OFF
TIME
ON
/QUIET
9
10
11
12
13
14
17
8
22
23
24
25
19
20
21
18
7
6
SWING
Operation mode
AUTO
FAN
COOL DRY
Remote controller
2. Signal sending display
4.FAN SPEED display
5. LOCK display
6. TIMER OFF display
TIMER ON display
7. TEMP display
3. SWING display
LO MED HI
AUTO
Display
circulated
8.
Additional functions display
Operation mode
Remote controller
QUIET
TURBO
SLEEP
Supplemented
electrical
heating
HEALTH
9. TURBO/QUIET button
FAN button
11. COOL button
FAN SPEED button
LOCK
button
Control the lightening and extinguishing
of the indoor LED display board.
17. LIGHT button
19. DRY button
displa
SWING UP/DOWN
button
23.HEALTH AIR FLOW
button
24.CANCEL/CONFIRM button
Function: Setting and cancel to the
timer and other additional functions.
25. RESET button
When the remote controller appears
abnormal, use a sharp pointed
article to press this button to reset
the remote.
Healthy function is not available for some units.
Loading of the battery
1
2
3
4
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the rece-
iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or
room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
TURBO
Display board
(adjust left and
ow)
Vertical blade
right air fl
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
Outlet
Inlet grille
Display board
1
4
2
3
5
Signal receiver hole
ON/OFF display
4
2
3
1
5
TIMER ON\OFF display
SLEEP display
Ambient temp.display
When receiving the remote
control signal, display the set
displayed.
time the room temperature is
temperature and in the rest
Note to the power failure resume:
press the sleep button ten times in five seconds
and enter function after hearing four sounds.And
press the sleep button ten times within five
seconds and leave this function after hearing
TIMER ON-OFF display
COOL\HEAT\Dry\AUTO display
two sounds.
(adjust left and
ow)
Vertical blade
r
ight air fl
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
Outlet
Inlet grille
6
5
2
1
4
3
6
4
2
1
5
3
(inside)
Power indicator
Timer mode indicator
Operation mode indicator
(Lights up when unit starts.)
(Lights up whenTimer operation is selected.)
(lights up when the compressor is on.)
Remote signal receiver
(A beeping sound is generated when a signal
from remote controller isreceived.)
Ambient temp display
When receiving the remote control signal, display the set
temperature and in the rest time the room temperature is
displayed and this room temperature is only for reference.
7
11
10
8
9
Anion generator
12
9
10
11
12
13
13