Haier HDU-42HT03/H Air Conditioner User Manual


 
5
1. Applicable ambient temperature range:
The machine is adaptive in following situation
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person.
3. The wiring method should be in line with the local wiring standard.
4. The power cable and connecting cable are self-provided. The power cable should be
H05RN-F 5G 2.5mm
2
.The connecting cable should be H07RN-F 4G 0.75mm
2
(HDU-
42CF03/H,HDU-42HT03/H),6G 0.75mm
2
(HDU-42HF03/H).During installation,
when the connecting cables break off, it must be assured that the grouding wire is the last
one to be broken off.
5. The breaker of the air conditioner should be all-pole switch; and the distance between its
two contacts should be no less 3mm.
6. The indoor unit installation height is at least 2.5m.
Safety Precautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 6
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
29 32 18
19 23 14
46 52 10
24 31 6
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
1
2
HDU-42CF03/H HDU-42HF03/H (FOR T1 Climate)
HDU-42HT03/H (FOR T3 Climate)