Haier FCD-JTHC50-E Water Heater User Manual


 
(Fig.4)
(Fig.5)
During installation, adequate space must be reserved for future maintenance and
repair. If the water heater is installed within decoration boards, the right board shall be
removable to facilitate removing the plastic cover during maintenance.
City water inlet pressure shall not be less than 0.05 Mpa.
Electric water heater shall be installed indoors with ambient temperature above 0 .
The pipes shall be collectively laid. Hot water outlet shall not be too far from use points.
In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat
loss.
The mounting wall shall be firm and reliable to support twice the weight of water heater
full of water. Non-load bearing walls or air brick walls must have corresponding
protective measures like additional support, wall-through screws or back boards.
Electric water heater shall be located in a place easy for use, maintenance and with a
floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be
damaged. The installation location shall avoid being above toilet bowl, bathtub,
washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.
Power socket for water heater shall be in a dry place free of water splash. (splash-
proof box is preferred)
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at
designated position with no random modification.
Installation
Attentions in Installation
Safety Precautions
Haier
C
Á¢
¼´ÓÃÓÚÏ´
Ô¡
²»
¿É
ÒÔ
²»
¿É
ÒÔ
Á¢¼´
ÓÃ
ÓÚ
Ï´
Ô¡
The product adopts Haier Safe Care patented technology. In normal installation, even in
severe case that ground wire is live due to wrong connection, the product Safe Care
technology can filter and efficiently ensure your safety. However, whenever your feel a
sensory current, please pull out the power plug and notify local after-service men in time. Do
not dismantle by yourself.
In winter in cold regions, for long-term out-
of-use, please lift the safety valve handle to
empty the water, avoiding ice formation
damaging the water heater.
Damaged power cord must be replaced
by after-service technicians with special
cable (factory provided). Other persons
shall not dismantle or repair. In addition,
do not place flammable matters nearby
the water heater.
Check if power meter and wire size are
consistent with water heater rated current.
If necessary, ask experienced qualified
electricians to check.
The water heater shall use a.c 220 V / 50 Hz
power supply from a separate socket (no
multi-purpose socket) and be reliably
grounded. The power socket shall meet
national standard requirements. Power plug
pins shall be cleaned in time to avoid any
contamination causing accidents like fire.
Do not use damaged wire, socket or
appliances with loose plug, otherwise
accidents like electric shock, short circuit
and fire may occur. Make sure power plug
closely fits with power socket.
²»
ÐÐ
£¡
²»ÐÐ
Power socket for water heater shall be
located in a dry place free of water spray.
Do not insert or pull the power plug with
wet hands, for accidents like electric
shock or injury may happen.
For first use after installation, the tank
must be full of water before connecting the
power. Otherwise, heating element
overheat may cause troubles.Children
taking shower must be attended by adults.
Please do not point the showerhead
towards human body when turning on or
off the faucet, avoiding to be scalded by a
small stream of hot water.
Connect to drain hose
Never do that
Be sure to act as per instructions
Description of the Symbols
Connection and Use of Safety Valve:
The safety valve should be connected to the cold water inlet pipe. Please check
carefully if the direction is correct after installation. The correct direction of
installation is that the arrowhead on the safety valve should point to the water heater.
If your water heater is not installed in a bathroom with sewage drain, please connect
the drain hose to the safety valve. Connect one end of the hose to the safety valve
vent and the other end to the sewage drain. The hose can be cut short or extended as
necessary. The hose shall be installed as inclined downward.
The water may drip from the discharge pipe of the pressure relied device and that this
pipe must be installed in a continuously downward direction and in a frost-free
environment. Check safety valve once a month as follow: move the small handle of
safety valve, if there's water flowing out, safety valve is normal; if there's no water
flow, please contact local after-sales service station.
The pressure relief device is to be operated regularly to remove lime deposits and to
verify that it is not blocked.