Dimensions
3
Electric Circuit Diagram
(Figure 1)
Front view
Cutaway view
Bottom view
Model
Volume
Net
weight
a1
b1
c1
d1
e1
A Hot water outlet
B Cold water inlet
C Heating element
D Enamel tank
E Wall-mounting
bracket
f1
a1
b1
e1
D
E
E
C
C1
d1
f1
FCD-
JTHA60- (E)
335 mm
100 mm
444 mm
390 mm
802 mm
22.8kg
60L
197mm
50L
702 mm
444 mm
390 mm
100 mm 235 mm
20kg
197 mm
FCD-
JTHA50- (E)
220mm
100mm
391mm
365mm
673mm
18.5kg
40L
197mm
FCD-
JTHA40- (E)
A
B
Remarks:the permitted error limit of above parameters is 10%.
L
N
E
BT
HL
EH
E
MT
L:Brown wire
N:Blue wire
MT: High temperature limiter
BT: Thermostat
HL:Heating indicator
EH:Heating element
E:Yellow/green wire
Parameters
Rated voltage: 220V~,50Hz Dimension: (See to Figure 1)
Power: 1500W Weight: (See to Figure 1)
Rated pressure: 0.65 / 0.75MPa Volume: (See to Figure 1)
Waterproof grade: IPX 4 ( ) Tap water pressure: no less than 0.05MPa
For the first use after installation, due to there's no water within the tank, first the city
water inlet valve and mixing valve must be opened. Close the mixing valve when water
flows out continuously from the showerhead or other outlets (the tank is full). Check
connections are free of water leakage, and insert the power plug.
Turn the knob to set your desired water heating temperature, which can be stepless
changed between cold water inlet temperature and 75 . In heating mode, heating lamp
is lighted on. Normally the knob shall be positioned at highest temperature. This
machine has a thermostat function, which automatically switches off the water heater
when temperature reaches the setting value, and switch on again when water
temperature decreases to certain value.
City water pressure 0.75 MPa will cause much water flowing out from safety valve
pressure relief vent. This is due to too high water pressure. Please ask after-sales
service for correction. The rated pressure of FCD-JTHA40- (E) is 0.65 MPa
Operation Instructions
To avoid causing machine troubles, do not connect power before tank is full of water.
Adjust a suitable temperature before use, for water temperature above 50 may burn
your skin.
This product is closed water heater, which can supply hot water through pipe
connection to several points like bathroom (bathtub, washbasin, showerhead) and
kitchen.
Heating adjustment can be made flexibly all year round adapting to climate changes. In
long-term out-of-use or maintenance, you can close city water pipe valve, open mixing
valve to hot water range, and move up safety valve handle to drain the tank. To avoid
injury, before next use, it is suggested to first open hot water valve before switching on
the water heater, exhausting gas possibly retained in the pipeline. In this case, no
smoke or fire is permitted near the open valve. Carefully check and confirm all parts are
in good condition.
Provided hot water quantity can meet use demand, temperature setting shall be
possibly low. It can minimize heat dissipation, high-temperature corrosion and
sedimentation, ensuring a longer service life.
Regularly ask servicemen to make safety inspection, remove sediment on heating
elements, and check consumption of anode bar. Too much consumed anode bar shall
be replaced.
1.
2.
3.
4.
5.
6.
Attentions in Operation