Haier ESA3087 Air Conditioner User Manual


 
OFF
FAN
COOL
ON
HIGH
LOW
MODE SPEED
TIMER
POWER
ON/OFF
TEMP / TIME
MODE SPEED
TIMER
POWER
TEMP / TIME
OFF
FAN
COOL
ON
HIGH
LOW
MODE SPEED
TIMER
POWER
ON/OFF
TEMP / TIME
OFFCOOL ONLY
FAN ONLY ONHIGH
MED
DEHUM
ENERGY
SAVER
LOW
ON/OFF
Once the mode function is established, you will have to set the fan speed. (See fig. #4)
Every time you press the SPEED button, fan speed will change between LOW, MED, and
HIGH.
1) If you choose the COOL mode you can run the fan in one of the 3 speeds: HIGH, MED,
or LOW.
2) For cool days you may want to run the "FAN" function. Here the fan runs at one of 3
speeds (HIGH fan, MED fan, LOW fan) as desired by you.
3) The dehumidify function removes excess moisture from the air on excessively humid days.
Tr: temperature inside the room.
Ts: the set temperature.
1) When Tr>Ts+3
o
F, the compressor will run the fan continuously at the selected speed.
2) When Ts-1
o
F*Tr*Ts+3
o
F, the compressor will cycle for 10 minutes on and 6 minutes off.
3) When Tr<Ts-1
o
F, the compressor will shut off. The dehumidification process takes place
between the set temperature-1 and 3
o
F above the set temperature.
4) Energy Saver: The unit runs the same as the COOL setting in the ENERGY SAVER mode.
But the fan will be off 3 minutes after the compressor cycles off.
10