Installation Procedure
Indoor Unit
Installation of indoor unit
Place where it is easy to route drainage pipe and outdoor piping.
Place away from heat source and with less direct sunlight.
Place where cool and warm air could be delivered evenly to every corner of the room.
Place near power supply socket. Leave enough space around the unit (refer to installation drawings).
Wall hole should be decided according to installtion place
and piping direction. (refer to installation drawings)
3.Fixing of indoor unit
INDOOR SIDE OUTDOOR SIDE
wall hole
wall thickness
( Cross section of wall hole )
70mm
With the unit set up vertically, fix the fitting metal to the unit
with screws, then fix the fitting metal to the wall with cement
nail and washer, as shown right:
Selection of indoor unit installation place
1.Position of the wall hole
Drill a hole of 70mm dia. with a little slope towards outside.
Install piping hole cover and seal it with putty after installation.
2.Making a wall hole
Moreover, if wanting to fix the unit more firmly, you should
fix the bottom panel to the ground with concrete bolts, as
shown right:
330
2- 10 hole
Screw
Fitting metal
Cement nail
Fitting hole
Bottom Panel
4- 14 hole 30 depth
260
130
79202
(202)
(79)