2. If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
5. The power cable and connecting cable are self-provided. The power cable parameter
is:
1) H07RN-F 5G 2.5mm
2
(380-400V, 3N~, 50Hz),(AD42NAMBEA(ECO)
AD36NAMBEA(ECO)AD28NAMBEA(ECO) ) ;
2) H05RN-F 3G 4.0mm
2
(1PH,220-230V~,50Hz)(AD28NAMBEA(ECO)
AD242AMBEA(ECO));
3) H05RN-F 3G 2.5mm
2
(1PH,220-230V~,50Hz)(AD182AMBEA(ECO)).
The connecting cable should be H05RN-F 4x0.75mm
2
All the cables shall have got the European authentication certificate. During installation,
when the connecting cables break off, it must be assured that the grouding wire is the
last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between
its two contacts should be no less 3mm.
7. The indoor unit installation height is at least 2.5m.
8. The air breaker and the power switch should installed the converiently reachable place
for user.