20
Installation of Indoor Unit
ELECTRICAL WIRING
HOW TO CONNECT WIRING TO THE TERMINALS
(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to
about 15/16"(25mm) of expose the solid wire.
(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
(3)Using pliers,bend the solid wire to form a loop suitable for the terminal screw.
B.For strand wiring
(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to
about 3/8"(10mm) of expose the solid wire.
(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
A.For solid core wiring (or F-cable)
Screw with
special washer
Round
terminal
Wire
Terminal
board
Screw with
special washer
Round
terminal
Wire
A. Solid wire
B. Strand wire
Round terminal
Loop
Insulation
Strip 15/16"(25mm)
Strip 15/16"(25mm)
After passing the connection cord and power cable through the insulation tube, fasten
it with the cord clamp, as shown in Fig.15
HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD
CLAMP
Fig. 14