REMOTE SYSTEM WIRING DIAGRAMS
This thermostat has been preprogrammed with energy saving program schedules in accordance with the
ENERGY STAR
®
program. When used with a remote system, HAI recommends that the Program Mode be
configured as “None” or “Occupancy”. This will disable the internal program schedules.
HAI HOME CONTROL SYSTEMS
The thermostat can be connected to an HAI Home Control system. The controller can send commands to the
thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items.
Run a 3 (or 4) conductor wire from the HAI system to the thermostat location. All thermostats on an HAI
Home Control system are connected to Ground, Zone +16, and Output 8 - See Figure 11.
THERMOSTAT
Leave Jumper
Connected
CONTROLLER
Black
Green
Yellow
UP
Figure 11 – Connections to HAI Home Control System
Notes:
1. Additional thermostats are connected in parallel. They may be connected in home-run or daisy chain
configuration.
2. When connecting to an HAI Home Control System, the metal jumper between terminal labeled “N/C”
and the terminal labeled “Black” on the right terminal strip must remain in place – See Figure 11.
3. All thermostats on an OmniLT controller are connected to the GRN (Green), BLK (Black), and YEL
(Yellow) terminals under the section marked "TSTAT".