ELECTRICAL POWER SUPPLY
Fill System Control Box Electrical Load Information
The following charts provide information for
the electrician wiring the grain dryer, and are a
reference guide for parts. It is recommended
that you contact your local power company and
have a representative survey the installation to
see that your wiring is compatible with their
system and that adequate power is supplied to
your unit. Remember that the only thing
connected to the recommended service amps
should be your grain dryer. Standard electrical
safety should be used. (Refer to the National
Electrical Code Standard handbook by the
National Fire Protection Association.) A
qualified electrician should make all electrical
wiring installations.
Fill System
HP Voltage
Full Load
Amps
Motor
Starter
Relay
Heater
Strips
220v1ph 13 30 C137B
3 HP 220v3ph 7 30 C104B
380v50hz 4 30 C630A
460v3ph 4 30 C630A
575v3ph 3 30 C630A
220v1ph 21 30 C228B
5 HP 220v3ph 12 30 C163B
380v50hz 7 30 C955A
460v3ph 6 30 C778A
575v3ph 5 30 C630A
220v1ph 32 40 C303B
7.5 HP 220v3ph 18 30 C228B
380v50hz 11 30 C151B
460v3ph 9 30 C125B
575v3ph 7 30 C955B
220v1ph 42 60 C366B
10 HP 220v3ph 25 30 C303B
380v50hz 14 30 C180B
460v3ph 12 30 C163B
575v3ph 9 30 C137B
220v1ph 64 75 F658B
15 HP 220v3ph 37 40 C400B
380v50hz 21 30 C273B
460v3ph 18 30 C214B
575v3ph 14 30 C180B
220v3ph 49 60 C500B
20 HP 380v50hz 28 40 C330B
460v3ph 23 30 C303B
575v3ph 19 30 C228B
220v3ph 61 75 F719B
25 HP 380v50hz 35 40 C400B
460v3ph 29 40 C330B
575v3ph 23 30 C273B
220v3ph 73 75 F772B
30 HP 380v50hz 43 60 C440B
460v3ph 35 40 C400B
575v3ph 28 40 C330B
Fill System
HP Voltage
Full Load
Amps
Motor
Starter
Relay
Heater
Strips