Graco Inc. 260100 Septic System User Manual


 
Technical Data
10 311305E
Technical Data
Maximum Working Pressure 65 psi (0.45 MPa, 4.5 bar)
Automatic Relief Setting Models 260100, 260101, 260104:
65 psi (0.45 MPa, 4.5 bar)
Model 260102:
30 psi (0.21 MPa, 2.1 bar)
Output Flow Model 260100: 5.8 gpm (22.0 lpm)
Model 260101: 4.25 gpm (16.15 lpm)
Model 260102*: 8.0 gpm (30.3 lpm)
Model 260104: 4.25 gpm (16.15 lpm)
Inlet Size 1 in. npt
Outlet Size 3/4 in. npt
Weight Model 260100: 34 lb (15.3 kg)
Models 260101, 260102, 260104:
25 lb (11.25 kg)
Dimensions See page 11
Voltage/current Model 260100: 12 VDC, 35 amps
Models 260101, 260102:
115 VAC, 60 Hz, 9.2 amps
Model 260104: 230 VAC, 50/60 Hz, 4 amps
Power Cord Model 260101, 260102 only: 30 in. (762 mm)
Hose size 8 ft (2.4 m), 3/4 in. (19 mm) ID
Suction tube 34 in. (864 mm)
Wetted parts carbon steel with zinc plating, stainless steel,
galvanized steel, aluminum, nitrile, rubber, PVC,
PVC cement
*Model 260102 is intended for use with fluid viscosities of 1000 centistokes (5000 ssu) or less.
For fluids with viscosities greater than 1000 centistokes use pump model 260101.