Graco Model Nos. 240-349 Pet Fence User Manual


 
308-8452
Table
of Contents
Warnings 2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setup 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts
List and Parts Drawing
240–349 to 240–353
10.
. . . . . . . . . . . . . . . . .
240–361
and 240–363
12.
. . . . . . . . . . . . . . .
Fluid
Filter Kit 240–440
14.
. . . . . . . . . . . . . . . . . .
Technical
Data
15.
. . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions 15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall
Mounting Hole Layout
15.
. . . . . . . . . . . . . . .
Graco
Standard W
arranty 16.
. . . . . . . . . . . . . . . .
Graco
Phone Number
16.
. . . . . . . . . . . . . . . . . . . .
Symbols
Warning Symbol
WARNING
WARNING
This
symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This
symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
corresponding instructions.
WARNING
PRESSURIZED FLUID HAZARD
Spray
from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin
and cause serious injury
.
D
Do not stop or deflect fluid leaks with your hand, glove, or rag.
D
Follow the
Pressure Relief Procedure
on page 6 before cleaning, checking, or servicing the
equipment.
D T
ighten all fluid connections before each use.
D
Check the hoses, tubes, and couplings daily
. Replace parts immediately if worn, damaged, or
loose. Permanently coupled hoses cannot be repaired.
FIRE AND EXPLOSION HAZARD
Improper
grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and
result in fire or explosion and serious injury
.
D
Ground the equipment, personnel in or close to the spray area, the object being sprayed, and all
other electrically conductive objects in the spray area. See
Grounding
on page 5.
D
If there is any static sparking while using the equipment,
stop spraying immediately
. Identify and
correct the problem.
D
Provide fresh air ventilation to avoid the buildup of flammable vapors from the solvent or the fluid
being sprayed.
D
Do not smoke in the spray area.
D
Extinguish all open flames or pilot lights in the spray area.
D
Do not turn on or of
f any light switch in the spray area.
D
Electrically disconnect all equipment in the spray area.
D
Keep the spray area free of debris, including solvent, rags, and gasoline.
D
Do not operate a gasoline engine in the spray area.