9308797
Installation
Changing the Orientation of the Fluid Inlet
and Outlet Ports
Fig. 4. You can change the orientation o f the fluid inlet
and outlet ports by repositioning the manifolds.
1.
Relieve the pressure. See Pres-
sure Relief Procedure on page 10.
2. Remove four manifold bolts (105).
3. T urn manifold to desired position, reinstall bolts,
and torque to 80 to 90 in-lb (9 to 10 NSm). See
Torque Sequence, page 20.
NOTE: Make sure all manifold o-rings are posi-
tioned correctly before you fasten the manifold.
Manifold o-rings (139) are shown in Fig. 6.
Fig. 4
1
Torqueto80to90in-lb(9to10NSm). See
Torque Sequence, page 20.
1
105
9071A
outlet
inlet
1
105