Graco 258907 Heat Pump User Manual


 
Setup
8 3A0245B
NOTE: JOB scrolls past, then the number of gallons dis-
pensed displays.
2. Press and hold to reset to zero.
Lifetime Gallons
1. Short press DTS button to move to LIFE gallons (or
liters x 10). LIFE scrolls briefly, then the number of
gallons dispensed displays.
Learn the Controller
This unit uses two different controllers: an inline valve con-
troller for taping and corner finishing, and a box slide con-
troller for box finishing. Each time you change controllers,
perform the following steps so the unit can learn the con-
troller.
1. Turn flow control knob fully counterclockwise to OFF
position.
2. Push digital display button 3 times until LEARN
appears on display screen.
3. Pull trigger on controller.
4. OK will then appear on display screen (if not, see
Troubleshooting).
NOTE: You must be facing the unit and be no more than 10
ft away to learn the controller. The unit can only be
operated by one learned controller at a time.
Secondary Menu - Stored Data
1. Perform Pressure Relief Procedure, see page 6.
2. To access Secondary Menu, make sure flow control
knob is turned fully counter-clockwise to the OFF
position. Then turn power switch on while holding
DTS button down.
3. SERIAL NUMBER scrolls past and then serial num-
ber (e.g. 00001) displays.
4. Short press DTS button and MOTOR HOURS
scrolls past and then total motor run hours are dis-
played.
5. Short press DTS button. LAST ERROR CODE
scrolls by and last error code is displayed (e.g.
E=07). See Electrical Problems, page 19.