14 308797
Service
Ball Check Valves
NOTE: Fluid Section Repair Kit D05977 is available.
See page 21 to order the correct kit for your pump.
Parts included in the kit are marked with a double
dagger (}) in Fig. 6 and in the Parts Drawings and
Lists. General purpose g rease 111920 and Adhesive
113500 are supplied in the kit.
1. Relieve the pressure. See
Pressure Relief Procedure on
page 10.
2. Remove the top and bottom manifolds (102, 103).
3. Remove all parts shown with a dagger (})Fig.6.
4. Clean all parts, and replace worn or damaged
parts.
5. Reassemble the pump.
NOTE: Torque the manifold bolts (105) to 80 to 90
in-lb(9to10NSm). See Torque Sequence, page
20.