Goodmans RT6212008x5 Heat Pump User Manual


 
6
GSH130[36-60]3*
GSH130[48-60]4*
HEAT PUMP SPECIFICATIONS
(1)
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection: Must use fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units that require a TXV Kit to be installed on the indoor coil: PLEASE NOTE: THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT
NOT THE INDOOR COIL
GSH130363AE
GSH130363AF
GSH130483AE
GSH130603AC
GSH130484AC
GSH130604AC
Cooling Capacity, BTUH 35,000 31,400 45,000 55,500 45,000 55,500
Compressor
R.L. Amps 9.0 9.9 12.4 17.3 5.8 6.7
L.R. Amps 65.5 73.0 88.0 123.0 44.0 49.5
Loss of Charge Pressure Switch
Open / Close 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG
Condenser Fan Motor
Horsepower 1/4 1/4 1/4 1/6 1/4 1/6
F.L. Amps 1.5 1.5 1.5 1.1 0.8 0.6
Liquid Line, Inches O.D. 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
Suction Line, Inches O.D. 7/8" 7/8" 7/8" 7/8" 7/8" 7/8"
Refrigerant Charge 188 188 223 233 223 233
Power Supply 208/230-60-3 208/230-60-3 208/230-60-3 208/230-60-3 460-60-3 460-60-3
Minimum Circuit Ampacity
(1)
12.7 13.9 17.1 22.7 8.0 9.0
Maximum Overcurrent Device
(2)
20 20 20 40 15 15
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4
Approximate Shipping Weight 207 207 225 266 225 266