Goodman Mfg SSZ160601A Heat Pump User Manual


 
8
COOLING PERFORMANCE DATA
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: SSZ160361A* / CA*F4860*6A* + TXV / MBE2000**-1 Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 - 30.0 31.1 34.0 - 27.8 28.8 31.5 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -
Delta T 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
1350 KW 1.98 2.03 2.09 - 2.14 2.19 2.26 - 2.28 2.33 2.40 - 2.40 2.45 2.53 - 2.50 2.56 2.64 - 2.59 2.65 2.74 -
AMPS 7.7 7.9 8.2 - 8.3 8.5 8.8 - 9.0 9.3 9.6 - 9.6 9.9 10.2 - 10.3 10.5 10.9 - 10.9 11.1 11.5 -
HI PR 217 233 246 - 243 261 276 - 276 297 314 - 315 339 358 - 354 381 402 - 391 421 445 -
LO PR 108 115 126 - 114 122 133 - 119 126 138 - 125 133 145 - 131 139 152 - 135 144 157 -
MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 35.6 - 30.6 31.7 34.8 - 29.1 30.2 33.0 - 26.9 27.9 30.6 -
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
Delta T 18 16 12 - 18 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 1200 KW 1.97 2.01 2.07 - 2.12 2.17 2.24 - 2.26 2.31 2.38 - 2.38 2.43 2.51 - 2.48 2.53 2.62 - 2.57 2.62 2.71 -
AMPS 7.7 7.8 8.1 - 8.3 8.5 8.7 - 9.0 9.2 9.5 - 9.6 9.8 10.1 - 10.2 10.4 10.8 - 10.8 11.0 11.4 -
HI PR 214 231 244 - 241 259 273 - 274 294 311 - 312 335 354 - 351 377 398 - 387 417 440 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 143 - 129 138 150 - 134 142 156 -
MBh 30.4 31.5 34.5 - 29.7 30.8 33.7 - 29.0 30.0 32.9 - 28.3 29.3 32.1 - 26.9 27.8 30.5 - 24.9 25.8 28.2 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
1050 KW 1.92 1.96 2.02 - 2.07 2.11 2.18 - 2.20 2.25 2.32 - 2.32 2.37 2.45 - 2.42 2.47 2.55 - 2.50 2.56 2.64 -
AMPS 7.4 7.6 7.9 - 8.0 8.2 8.5 - 8.7 8.9 9.2 - 9.3 9.5 9.8 - 9.9 10.1 10.5 - 10.5 10.7 11.1 -
HI PR 208 224 236 - 233 251 265 - 265 286 302 - 302 325 343 - 340 366 386 - 376 404 427 -
LO PR 104 111 121 - 110 117 127 - 114 121 132 - 120 127 139 - 126 134 146 - 130 138 151 -
MBh 34.5 35.5 38.4 41.2 33.7 34.7 37.5 40.3 32.9 33.8 36.6 39.3 32.1 33.0 35.7 38.4 30.5 31.4 34.0 36.4 28.2 29.1 31.5 33.8
S/T 0.86 0.77 0.58 0.38 0.89 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43
Delta T20 19 1511 21 1915 11 21 19 151121 19 16 11 20 19 15 11 19 18 14 10
1350 KW 2.00 2.04 2.11 2.18 2.16 2.20 2.28 2.35 2.29 2.35 2.42 2.51 2.42 2.47 2.55 2.64 2.52 2.58 2.66 2.76 2.61 2.67 2.76 2.86
AMPS 7.8 8.0 8.2 8.5 8.4 8.6 8.9 9.2 9.1 9.3 9.6 10.0 9.7 10.0 10.3 10.7 10.4 10.6 11.0 11.4 11.0 11.2 11.6 12.0
HI PR 219 235 249 259 245 264 279 291 279 300 317 331 318 342 361 377 358 385 406 424 395 425 449 468
LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169
MBh 33.5 34.5 37.3 40.0 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.1 32.1 34.7 37.2 29.6 30.5 33.0 35.4 27.4 28.2 30.5 32.8
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.85 0.64 0.41
Delta T21 19 1611 21 2016 11 21 20 161122 20 16 11 21 20 16 11 20 18 15 10
75 1200 KW 1.98 2.03 2.09 2.16 2.14 2.19 2.26 2.33 2.28 2.33 2.40 2.48 2.40 2.45 2.53 2.62 2.50 2.56 2.64 2.73 2.59 2.65 2.74 2.83
AMPS 7.7 7.9 8.2 8.5 8.3 8.5 8.8 9.1 9.0 9.3 9.6 9.9 9.6 9.9 10.2 10.6 10.3 10.5 10.9 11.3 10.9 11.1 11.5 11.9
HI PR 217 233 246 257 243 261 276 288 276 297 314 328 315 339 358 373 354 381 402 420 391 421 445 464
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125
133
145 154 131 139 152 162 135 144 157 167
MBh 30.9 31.8 34.4 37.0 30.2 31.1 33.6 36.1 29.5 30.3 32.8 35.2 28.7
29.6
32.0 34.4 27.3 28.1 30.4 32.7 25.3 26.0 28.2 30.3
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40
Delta T21 20 1611 22 2016 11 22 20 161122 20 17 11 22 20 16 11 20 19 15 11
1050 KW 1.94 1.98 2.04 2.11 2.09 2.13 2.20 2.27 2.22 2.27 2.34 2.42 2.34 2.39 2.47 2.55 2.44 2.49 2.57 2.66 2.52 2.58 2.67 2.76
AMPS 7.5 7.7 7.9 8.2 8.1 8.3 8.6 8.9 8.8 9.0 9.3 9.6 9.4 9.6 9.9 10.3 10.0 10.2 10.6 11.0 10.6 10.8 11.2 11.6
HI PR 210 226 239 249 236 254 268 279 268 288 305 318 305 329 347 362 343 370 390 407 380 408 431 450
LO PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.
SSZ160361A*