Goodman Mfg SSZ160481A Heat Pump User Manual


 
10
COOLING PERFORMANCE DATA
SSZ160481A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: SSZ160481A* / CA*F4860*6A* + TXV / MBE2000**-1 Design Subcooling 7 ± 2 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159 63 677159 63 67 715963677159636771
MBh 46.5 48.2 52.9 - 45.5 47.1 51.6 - 44.4 46.0 50.4 - 43.3 44.9 49.2 - 41.1 42.6 46.7 - 38.1 39.5 43.3 -
S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.89 0.74 0.51 -
DeltaT 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 13 - 18 15 12 -
1744 KW 2.68 2.73 2.82 - 2.88 2.94 3.04 - 3.06 3.13 3.23 - 3.22 3.29 3.40 - 3.35 3.43 3.54 - 3.47 3.55 3.66 -
AMPS 10.2 10.4 10.8 - 11.0 11.3 11.6 - 11.9 12.2 12.6 - 12.8 13.1 13.5 - 13.6 13.9 14.4 - 14.4 14.8 15.3 -
HI PR 213 229 242 - 239 257 271 - 272 292 309 - 309 333 351 - 348 374 395 - 384 414 437 -
LO PR 110 117 128 - 116 124 135 - 121 128 140 - 127 135 147 - 133 141 154 - 137 146 160 -
MBh 45.2 46.8 51.3 - 44.1 45.7 50.1 - 43.1 44.7 48.9 - 42.0 43.6 47.7 - 39.9 41.4 45.4 - 37.0 38.3 42.0 -
S/T 0.74 0.61 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.84 0.70 0.48 - 0.85 0.71 0.49 -
DeltaT 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 16 12 -
70 1550 KW 2.66 2.71 2.80 - 2.86 2.92 3.01 - 3.04 3.10 3.20 - 3.19 3.26 3.37 - 3.33 3.40 3.51 - 3.44 3.52 3.63 -
AMPS 10.1 10.3 10.7 - 10.9 11.2 11.5 - 11.8 12.1 12.5 - 12.7 13.0 13.4 - 13.5 13.8 14.3 - 14.3 14.6 15.1 -
HI PR 211 227 239 - 236 254 269 - 269 289 306 - 306 330 348 - 345 371 391 - 381 410 433 -
LO PR 109 116 126 - 115 122 134 - 119 127 139 - 126 134 146 - 132 140 153 - 136 145 158 -
MBh 41.7 43.2 47.4 - 40.7 42.2 46.3 - 39.8 41.2 45.2 - 38.8 40.2 44.1 - 36.9 38.2 41.9 - 34.1 35.4 38.8 -
S/T 0.71 0.59 0.41 - 0.74 0.61 0.43 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
DeltaT 20 17 13 - 20 18 13 - 20 18 13 - 20 18 13 - 20 17 13 - 19 16 12 -
1356 KW 2.60 2.65 2.73 - 2.79 2.85 2.94 - 2.96 3.03 3.12 - 3.11 3.18 3.28 - 3.24 3.31 3.42 - 3.35 3.43 3.54 -
AMPS 9.8 10.0 10.4 - 10.6 10.9 11.2 - 11.5 11.8 12.2 - 12.3 12.6 13.0 - 13.1 13.4 13.9 - 13.9 14.2 14.7 -
HI PR 204 220 232 - 229 247 261 - 261 281 296 - 297 320 338 - 334 360 380 - 369 397 420 -
LO PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 141 - 128 136 148 - 132 140 153 -
MBh 47.3 48.7 52.8 56.6 46.2 47.6 51.5 55.3 45.1 46.5 50.3 54.0 44.0 45.3 49.1 52.7 41.8 43.1 46.6 50.0 38.7 39.9 43.2 46.3
S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.93 0.83 0.63 0.41 0.96
0.86
0.65 0.42 1.00 0.89 0.68 0.44 1.00 0.90 0.68 0.44
DeltaT 22 20 17 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 11 20 19 16 11
1744 KW 2.70 2.76 2.84 2.93 2.90 2.97 3.06 3.16 3.09 3.15 3.25 3.36 3.25 3.32 3.42 3.54 3.38 3.46 3.57 3.69 3.50 3.58 3.69 3.82
AMPS 10.3 10.5 10.9 11.3 11.1 11.4 11.7 12.2 12.1 12.4 12.8 13.2 12.9 13.2 13.6 14.2 13.7 14.1 14.5 15.1 14.5 14.9 15.4 16.0
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 312 336 355 370 352 378 399 417 388 418 441 460
LO PR 111 118 129 137 117 125 136 145 122 130 142 151 128 136 149 158 134 143 156 166 139 148 161 172
MBh 46.0 47.3 51.2 55.0 44.9 46.2 50.0 53.7 43.8 45.1 48.8 52.4 42.8 44.0 47.6 51.1 40.6 41.8 45.3 48.6 37.6 38.7 41.9 45.0
S/T 0.84 0.75 0.57 0.36 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
DeltaT 23 21 17 12 23 21 17 12 23 21 17 12 23 21 18 12 23 21 17 12 21 20 16 11
75 1550 KW 2.68 2.73 2.82 2.91 2.88 2.94 3.04 3.13 3.06 3.13 3.23 3.33 3.22 3.29 3.40 3.51 3.35 3.43 3.54 3.66 3.47 3.55 3.66 3.79
AMPS 10.2 10.4 10.8 11.2 11.0 11.3 11.6 12.1 11.9 12.2 12.6 13.1 12.8 13.1 13.5 14.0 13.6 13.9 14.4 14.9 14.4 14.8 15.3 15.8
HI PR 213 229 242 252 239 257 271 283 272 292 309 322 309
333
352 367 348 375 395 412 385 414 437 456
LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170
MBh 42.4 43.7 47.3 50.7 41.4 42.7 46.2 49.6 40.4 41.6 45.1 48.4 39.5 40.6 44.0 47.2 37.5 38.6 41.8 44.8 34.7 35.8 38.7 41.5
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
DeltaT 23 21 18 12 23 22 18 12 24 22 18 12 24
22
18 12 23 21 18 12 22 20 16 11
1356 KW 2.62 2.67 2.75 2.84 2.81 2.87 2.96 3.06 2.99 3.05 3.15 3.25 3.14 3.21 3.31 3.42 3.27 3.34 3.45 3.57 3.38 3.46 3.57 3.69
AMPS 9.9 10.1 10.5 10.9 10.7 11.0 11.3 11.7 11.6 11.9 12.3 12.8 12.4 12.7 13.1 13.6 13.2 13.5 14.0 14.5 14.0 14.3 14.8 15.4
HI PR 206 222 235 245 232 249 263 275 263 284 299 312 300
323
341 356 338 363 384 400 373 401 424 442
LO PR 107 113 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 159 133 142 155 165
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.