COOLING PERFORMANCE DATA
SSZ160241A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: SSZ160241A* / CA*F3636*6A* + TXV / MBE1600**-1 Design Subcooling 7 ± 2 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
S/T 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.89 0.74 0.52 - 0.90 0.75 0.52 -
Delta T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -
984 KW 1.44 1.47 1.51 - 1.55 1.58 1.63 - 1.64 1.68 1.73 - 1.73 1.77 1.82 - 1.80 1.84 1.90 - 1.86 1.91 1.97 -
AMPS 5.6 5.7 5.9 - 6.0 6.2 6.3 - 6.5 6.7 6.9 - 6.9 7.1 7.3 - 7.4 7.5 7.8 - 7.8 8.0 8.2 -
HI PR 213 230 242 - 239 258 272 - 272 293 309 - 310 334 352 - 349 375 396 - 385 415 438 -
LO PR 112 119 130 - 118 125 137 - 122 130 142 - 129 137 149 - 135 143 157 - 139 148 162 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
S/T 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.86 0.72 0.50 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 875 KW 1.43 1.46 1.50 - 1.54 1.57 1.62 - 1.63 1.67 1.72 - 1.72 1.75 1.81 - 1.79 1.83 1.89 - 1.85 1.89 1.95 -
AMPS 5.5 5.7 5.8 - 6.0 6.1 6.3 - 6.5 6.6 6.8 - 6.9 7.0 7.3 - 7.3 7.5 7.7 - 7.7 7.9 8.2 -
HI PR 211 227 240 - 237 255 269 - 270 290 306 - 307 330 349 - 345 372 392 - 382 411 434 -
LO PR 110 117 128 - 117 124 136 - 121 129 141 - 127 136 148 - 133 142 155 - 138 147 160 -
MBh 21.1 21.8 23.9 - 20.6 21.3 23.4 - 20.1 20.8 22.8 - 19.6 20.3 22.3 - 18.6 19.3 21.1 - 17.3 17.9 19.6 -
S/T 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.83 0.69 0.48 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
766 KW 1.39 1.42 1.47 - 1.50 1.53 1.58 - 1.59 1.63 1.68 - 1.67 1.71 1.76 - 1.74 1.78 1.84 - 1.80 1.84 1.90 -
AMPS 5.4 5.5 5.7 - 5.8 5.9 6.1 - 6.3 6.4 6.6 - 6.7 6.9 7.1 - 7.1 7.3 7.5 - 7.5 7.7 7.9 -
HI PR 205 220 233 - 230 247 261 - 261 281 297 - 298 320 338 - 335 360 381 - 370 398 421 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 143 - 129 138 150 - 134 142 156 -
MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2 22.9 24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.890.800.600.390.920.820.620.400.940.850.640.410.98 0.87 0.66 0.42 1.00 0.91 0.69 0.44 1.00 0.91 0.69 0.44
Delta T20181510201915102019151020 19 15 11 20 18 15 10 18 17 14 10
984 KW 1.45 1.48 1.53 1.58 1.56 1.59 1.64 1.70 1.66 1.69 1.75 1.81 1.74 1.78 1.84 1.90 1.82 1.86 1.92 1.98 1.88 1.92 1.99 2.05
AMPS 5.6 5.8 5.9 6.2 6.1 6.2 6.4 6.6 6.6 6.7 6.9 7.2 7.0 7.2 7.4 7.7 7.4 7.6 7.9 8.1 7.9 8.0 8.3 8.6
HI PR 215 232 245 255 242 260 275 287 275 296 312 326 313
337
356 371 352 379 400 418 389 419 442 461
LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 168 141 150 164 174
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6
22.2
24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.850.760.570.370.880.790.590.380.900.810.610.390.93 0.83 0.63 0.41 0.97 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T21191611211916112119161121 19 16 11 21 19 16 11 19 18 15 10
75 875 KW 1.44 1.47 1.51 1.56 1.55 1.58 1.63 1.68 1.64 1.68 1.73 1.79 1.73 1.77 1.83 1.89 1.80 1.84 1.90 1.97 1.86 1.91 1.97 2.04
AMPS 5.6 5.7 5.9 6.1 6.0 6.2 6.3 6.6 6.5 6.7 6.9 7.1 6.9 7.1 7.3 7.6 7.4 7.5 7.8 8.1 7.8 8.0 8.2 8.5
HI PR 213 230 242 253 239 258 272 284 272 293 309 323 310 334 352 368 349 375 396 413 385 415 438 457
LO PR 112 119 130 138 118 125 137 146 122 130 142 152 129
137
149 159 135 143 157 167 139 148 162 173
MBh 21.4 22.1 23.9 25.6 20.9 21.6 23.3 25.0 20.4 21.0 22.8 24.4 19.9 20.5 22.2 23.8 18.9 19.5 21.1 22.7 17.5 18.1 19.6 21.0
S/T 0.820.730.550.360.850.760.570.370.870.780.590.380.90 0.80 0.61 0.39 0.93 0.83 0.63 0.41 0.94 0.84 0.64 0.41
Delta T21191611212016112120161121 20 16 11 21 19 16 11 20 18 15 10
766 KW 1.40 1.43 1.48 1.53 1.51 1.54 1.59 1.64 1.60 1.64 1.69 1.75 1.69
1.72
1.78 1.84 1.76 1.80 1.85 1.92 1.82 1.86 1.92 1.98
AMPS 5.4 5.6 5.7 5.9 5.9 6.0 6.2 6.4 6.3 6.5 6.7 6.9 6.8 6.9 7.1 7.4 7.2 7.3 7.6 7.9 7.6 7.8 8.0 8.3
HI PR 207 223 235 245 232 250 264 275 264 284 300 313 301 324 342 357 338 364 385 401 374 402 425 443
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.