COOLING PERFORMANCE DATA
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: SSZ160361A* / CA*F4860*6A* + TXV / MBE2000**-1 Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59 63 6771 59 6367 71 59 63 677159 63 67 715963677159636771
MBh 35.1 35.9 38.3 41.0 34.3 35.0 37.4 40.0 33.5 34.2 36.5 39.0 32.6 33.4 35.6 38.1 31.0 31.7 33.9 36.2 28.7 29.4 31.4 33.5
S/T 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.83 0.62
Delta T23 22 1915 23 2219 15 23 22 191522 23 19 152122191520201814
1350 KW 2.02 2.06 2.13 2.20 2.17 2.22 2.29 2.37 2.31 2.37 2.44 2.53 2.44 2.49 2.58 2.66 2.54 2.60 2.69 2.78 2.63 2.69 2.78 2.88
AMPS 7.9 8.0 8.3 8.6 8.5 8.7 9.0 9.3 9.2 9.4 9.7 10.1 9.8 10.1 10.4 10.8 10.4 10.7 11.1 11.5 11.1 11.3 11.7 12.2
HI PR 221 238 251 262 248 267 282 294 282 303 320 334 321 346 365 381 361 389 411 428 399 430 454 473
LO PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171
MBh 34.1 34.8 37.2 39.8 33.3 34.0 36.3 38.8 32.5 33.2 35.5 37.9 31.7 32.4 34.6 37.0 30.1 30.8 32.9 35.1 27.9 28.5 30.4 32.5
S/T 0.90 0.85 0.69 0.51 0.94 0.88 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.56 1.00 0.96 0.78 0.59 1.00 0.97 0.79 0.59
Delta T24 23 2016 24 2320 16 24 23 201624 23 20 16 23 23 20 16 21 21 18 15
80 1200 KW 2.00 2.04 2.11 2.18 2.16 2.20 2.28 2.35 2.30 2.35 2.42 2.51 2.42 2.47 2.55 2.64 2.52 2.58 2.66 2.76 2.61 2.67 2.76 2.86
AMPS 7.8 8.0 8.2 8.5 8.4 8.6 8.9 9.2 9.1 9.3 9.6 10.0 9.7 10.0 10.3 10.7 10.4 10.6 11.0 11.4 11.0 11.2 11.6 12.0
HI PR 219 235 249 259 245 264 279 291 279 300 317 331 318 342
361
377 358 385 406 424 395 425 449 468
LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169
MBh 31.4 32.1 34.3 36.7 30.7 31.4 33.5 35.8 30.0 30.6 32.7 35.0 29.3 29.9 31.9 34.1 27.8 28.4 30.3 32.4 25.7 26.3 28.1 30.0
S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.92 0.87 0.71 0.53 0.95 0.90 0.73 0.54 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
Delta T24 23 2016 24 2320 16 24 23 201624 23 20 162423201623221915
1050 KW 1.95 1.99 2.06 2.12 2.10 2.15 2.22 2.29 2.24 2.29 2.36 2.44 2.36 2.41 2.49 2.57 2.46 2.51 2.60 2.68 2.54 2.60 2.69 2.78
AMPS 7.6 7.8 8.0 8.3 8.2 8.4 8.6 9.0 8.9 9.1 9.4 9.7 9.5 9.7 10.0 10.4 10.1 10.3 10.7 11.1 10.7 10.9 11.3 11.7
HI PR 212 228 241 251 238 256 271 282 271 291 308 321 308 332 350 366 347 373 394 411 383 413 436 454
LO PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 158 133 141 154 164
MBh 35.71 36.40 38.12 40.67 34.88 35.55 37.23 39.72 34.04 34.70 36.35 38.78 33.21 33.86 35.46 37.83 31.55 32.16 33.69 35.94 29.23 29.79 31.20 33.29
S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80
Delta T24 24 2219 24 2423 20 23 24 232023 23 23 202122232020202118
1350 KW 2.03 2.08 2.14 2.21 2.19 2.24 2.31 2.39 2.33 2.39 2.46 2.55 2.46 2.51 2.60 2.69 2.56 2.62 2.71 2.80 2.66 2.72 2.81 2.91
AMPS 7.9 8.1 8.4 8.7 8.6 8.8 9.0 9.4 9.3 9.5 9.8 10.2 9.9 10.2 10.5 10.9 10.5 10.8 11.2 11.6 11.2 11.4 11.8 12.3
HI PR 223 240 254 264 250 269 285 297 285 306 324 338 324 349 369 384 365 393 415 432 403 434 458 478
LO PR 111 119 129 138 118 125 137 146 122 130 142 151 129 137 149 159 135 143 157 167 139 148 162 172
MBh 34.7 35.3 37.0 39.5 33.9 34.5 36.1 38.6 33.1 33.7 35.3 37.6 32.2 32.9 34.4 36.7 30.6 31.2 32.7 34.9 28.4 28.9 30.3 32.3
S/T 0.95 0.91 0.82 0.67 0.98 0.95 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
Delta T25 25 2320 25 2524 20 25 25 242025 25 24 212324242022222219
85 1200 KW 2.02 2.06 2.13 2.20 2.17 2.22 2.29 2.37 2.31 2.37 2.44 2.53 2.44 2.49 2.58 2.66 2.54 2.60 2.69 2.78 2.63 2.69 2.78 2.88
AMPS 7.9 8.0 8.3 8.6 8.5 8.7 9.0 9.3 9.2 9.4 9.7 10.1 9.8 10.1 10.4 10.8 10.4 10.7 11.1 11.5 11.1 11.3 11.7 12.2
HI PR 221 238 251 262 248 267 282 294 282 303 320 334 321 346 365 381 361 389 411 428 399 430 454 473
LO PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171
MBh 32.0 32.6 34.2 36.4 31.3 31.9 33.4 35.6 30.5 31.1 32.6 34.7 29.8 30.3 31.8 33.9 28.3 28.8 30.2 32.2 26.2 26.7 28.0 29.8
S/T 0.91 0.88 0.79 0.64 0.95 0.91 0.82 0.67 0.97 0.94 0.84 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74
Delta T26 25 2421 26 2524 21 26 25 242126 26 24 212525242123232219
1050 KW 1.97 2.01 2.07 2.14 2.12 2.17 2.24 2.31 2.26 2.31 2.38 2.46 2.38 2.43 2.51 2.60 2.48 2.53 2.62 2.71 2.57 2.62 2.71 2.81
AMPS 7.6 7.8 8.1 8.4 8.3 8.4 8.7 9.0 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.5 10.2 10.4 10.8 11.2 10.8 11.0 11.4 11.8
HI PR 214 231 244 254 240 259 273 285 273 294 311 324 311 335 354 369 350 377 398 415 387 417 440 459
LO PR 107 114 124 132 113 120 131 140 118 125 137 145 123 131 143 153 129 138 150 160 134 142 155 166
Shaded area is ARI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.
SSZ160361A*