Goodman Mfg GSH140181A Heat Pump User Manual


 
WIRING DIAGRAMS
25
TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,
OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.
WARNING
!
GSH140[18-60]1A*
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
3) CRANKCASE HEATER MAY BE
FACTORY OR FIELD INSTALLED.
COMP
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
IO
T1
C
M
A
I
N
R
A
U
X
5
S
SR
SA
2
1
RCCF
SC
T2
C
L1
L2
(IF USED)
C
H
C
F
M
A
I
N
A
U
X
IO
CM
LPS
VENDOR
: GOODMAN PRINT SHOP 07/05 0140R00019P
OR
YL
BL
RD
O
Y
C
R
NOTE 1
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
COMPONENT CODE
C --------------- CONTACTOR
CH ------------- CRANKCASE HEATER
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
DC ------------- DEFROST CONTROL
DFT ----------- DEFROST THERMOSTAT
HVDR -------- HIGH VOLTAGE DEFROST RELAY
IO -------------- INTERNAL OVERLOAD
LPS
------------ LOW PRESSURE SWITCH
LVDR --------- LOW VOLTAGE DEFROST RELAY
LVJB
---------- LOW VOLTAGE
JUNCTION BOX
RCCF
--------- RUN CAPACITOR FOR COMPRESSOR & FAN
RVC ----------- REVERSING VALVE COIL
SA ------------- START ASSIST
SC
------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
S
R
-------------
START RELAY FOR COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
T1
L1
T2
L2
ALTERNATE DOUBLE
POLE CONTACTOR
OUTDOOR POWER SUPPLY
SEE RATING PLATE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
RD
SA
(IF USED)
NOTE 2
LVJB
CONTROL BOX
SC
RD BL
L2
T2
L1
T1
C
BK
BK
BK
RD
RD
BK
BL
YL
YL
BL
RD
RCCF
F
C
HERM
YL
YL
YL
BR
RD
PU
YL
RD
SR
5
2
1
BK
YL
BL
IO
CM
AUX
MAIN
BK
BR
PU
YL
C
R
S
RD
BK
AUX
MAIN
COMP
BK
DFT
YLYL
LPS
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
DF1 DF2
HVDR
CH
(IF USED)
NOTE 3
W2
LVDR
O
R
O
O Y
C
RVC
W2
INDOOR POWER
SUPPLY
R
C
DFT
C
Y
DC
R
DFT
RVC
BK
RD
RD
BK
CH
(IF USED) NOTE 3
BK
BK BK
WH W2
DC
OR
C
Y
O O
BL
YL
BK
RD
R
R
RD
LVDR
W2
WH
DFT
RD
H
V
D
R
DF2
DF1
BK
BK
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.